Trim Selection
Documents  Introduction  9800 & F9800  9860 & F9860  LBR9860 & F9860
Selector Chart  Strikes & Accessories  Alarm Exit Hardware  Fire Exit Hardware 

Print Catalog Page

ANSI A156.3, Grade 1
Lever Design
  • Non handed Grade 1 (Clutch Style)
  • Cylindrical body hardened steel heavy duty tailpiece. For 1 3/4" and 2 1/4" doors. Prefix THI before part number for 2 1/4" door thickness. Available for fire and non fire rated rim and vertical rod exit devices.
  • Rose diameter 3 1/3", lever length 4 3/4". Fits and covers 161 cutout.
Lever Design AT Design Spa Design
TUB Design  
 
  • ENTOOL or ICENTOOL  - Entrance
    • Key retracts latchbolt, unlocks lever.
    • ANSI Function - 08
  • STRO5L or ICSTRO5l  - Storeroom
    • Key operates lever, otherwise always locked.
    • ANSI Function - 04
  • PAS30L - Passage
    • Trim always operable and free
    • ANSI Function - 15
  • DUM40L - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10

When ordering "AT" and "SPA" designs, prefix design name before part number. Example: ENTOOL in "AT" design is ATENTOOL.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

Escutcheon Lever Design

Construction

Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible. Hardened steel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

Finishes

Architectural plated finishes

Escutcheon Dimensions

2 5/16" width x 8 1/2" length. Lever length: 4 3/4". Fits and covers 2 1/8" 161 cutout.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

  • ESC9800 or ICESC9800 - Entrance
    • Key locks or unlocks lever.
    • ANSI Function - 63
  • ESC9805 or ICESC9805  - Storeroom
    • Key retracts latchbolt, otherwise always locked.
    • ANSI Function - 04
  • ESC9830 - Passage
    • Trim always operable and free
    • ANSI Function - 62
  • ESC9840 - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10
 
Pull Design
9800 NL or IC9800NL 9800 DTP 9800 EOP
  • For Rim Devices Only
  • Outside by pull and key.
  • Key retracts latchbolt.
  • ANSI function - 03
  • Covers 161 cutout.
  • Finishes
  • Outside by pull only.
  • Pull when dogged.
  • ANSI Function - 02
  • Covers 161 cutout.
  • Finishes
  • Outside by plate only.
  • ANSI function - 10
  • Covers 161 cutout.
  • Finishes

Thumbpiece Trim

  • 98TP00 or IC98TP00 - Entrance
    • Key locks or unlocks thumbpiece.
    • ANSI Function - 63
  • 98TP05 or IC98TP05  - Storeroom
    • Key retracts latchbolt, otherwise always locked.
    • ANSI Function - 04
  • 98TP30 - Passage
    • Trim always operable and free
    • ANSI Function - 62
  • 98TP40 - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10
Finishes

Architectural plated finishes

Door Thickness

Standard 1 3/4". Prefix THI before part number for 2 1/4 thick doors.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

Interchangeable Core - Interchangeable core locks will accept compatible 6 or 7 pin cores with Best, Falcon and Arrow. Indicated by "IC"

Electrified Lever Trim

Cal-Royal’s electrified lever trim provides remote locking and
unlocking capabilities while incorporating the patented clutch trim
design. The 24V DC solenoid can be energized from a distant
controller, thus allowing access control of the opening.
The control of stairwells in high-rise buildings is a common
application for this trim, where electric pullback of the exit
device’s latchbolt is cost prohibitive or not required. This is
especially practical in applications where fire/life safety codes
require a “fail-safe” condition which is not an option with
electrified latch pullback devices. Because the current draw is
quite low there is no need for a more expensive power supply to
provide the surge current.


Features

  • Continuous duty solenoids used to insure trouble-free operation
  • Internally mounted solenoid to ease installation (no special door prep required)
  • No hassle 3-Year Warranty


Options

  • Available Fail Safe (electrically locked) or Fail Secure (Electrically Unlocked)
  • Voltage options – 12V or 24V (AC/DC)
  • Request to Enter Switch (REE) available
  • CRU2 – Current Reduction Unit to improve solenoid life in “continuously on” applications

Specifications
Solenoid....................................... Continuous Duty 24VDC
Operating Voltage........................ 12 or 24VAC/DC + OR – 10% (must specify 12 or 24 volts when ordering)
Amperage..................................... 260mA@12V / 160mA@24V
Coil Resistance............................ 12V=49Ω / 24V=159Ω
 

To order, Specify:
OPTIONS: FAIL SAFE (FS)
              FAIL SECURE (FSE)

 

ITEM#          DESCRIPTION
FS 12 ESC    TRIM FS12 FAIL-SAFE OPTION 12V AC/DC
FS 24 ESC    TRIM FS24 FAIL-SAFE OPTION 24V AC/DC
FSE 12 ESC  TRIM FSE12 FAIL-SECURE OPTION 12V AC/DC
FSE 24 ESC  TRIM FSE24 FAIL-SECURE OPTION 24V AC/DC