ANSI A156.3, Grade 1
Specifications:
  • For Doors - 1-3/4" thick standard optional 2-1/4" thick. 3-3/4" minimum stile width required for single door application. 3-1/2" minimum stile width required for double door application. Lever trims available.
  • Chassis - Nonferrous alloy (Panic Grade), steel (Fire Grade)
  • Cover - Nonferrous alloy. Covers stock hollow metal doors with 161 cutout.
  • Mounting - Furnished standard with wood and machine screws. Thru bolts are standard packaging on fire rated devices.  Thru bolts are included and standard packaging on fire rated devices.
  • End Cap - Steel construction.
  • Alarm - Available. Prefix "Alrm" before part #.
  • Hand - Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
  • Latch Bolt - Stainless steel.
  • Spring - Stainless steel.
  • ANSI Standard - A156.3, Grade 1.
  • Rail Assembly - Heavy gauge steel, painted.
  • Strike - See Strike page.
  • Dogging Feature - Allen-type key furnished standard on non-fire labeled devices.
  • Mullion - Available.
  • UL and ULC Listed - 2260 Series for panic. F2260 Series for fire exit hardware for all types of 8' x 8' double doors for up to 3 hour fire labeled installations, conforms to standards UL10C and UBC 7-2-1997 codes.
  • Finish - Aluminum (alum), dark bronze duranodic (duro), gold.
  • Door Size - 2260V3694 and F2260V3684 for 36" x 84" doors. 2280V4896 and F2280V4896 for 48" x 96" doors. 2290V3696 and F2290V3696 for 36" x 96" doors. 2250V36120 for 36" x 120" doors. 2240V48120 for 48" x 120" doors.
 
Dimensions
Touchbar height to finished floor 41" (1043mm) at center
Touch bar projection - neutral 2 1/2" (64mm)
Touch Bar Projection - depressed 1 3/4" (45mm)
center case 5 1/8" x 2 3/4" x 2" (129mm x 69mm x 52mm)
Device length - Short 3' (914mm) 2'2" x 3' (840mm to 914mm) door size
Device Length - Long 4' (1219mm) 2'9" to 4' (1145mm to 1219mm) door size
panic grade top & bottom latch case 3 15/16" x 2 1/8" x 1 3/8" (100mm x 52mm x 42mm)
Fire Grade top latch case 3 15/6" x 2 11/16" x 2 1/16" (100mm x 68mm x 53mm)
Fire grade Bottom latch case 3 15/16" x 2 1/8" x 1 3/8" (100mm x 52mm x 42mm)
Top and bottom rod length for 36" x 84" doors top rod 43 1/4" (1100mm), bottom rod 37 3/4" (960mm)
top and bottom rod length for 48" x 96" doors top rod 53 1/16" (1350mm), bottom rod 37 3/4" (960mm)
vertical rods 1/2" (13mm) round tubing
Minimum Stile Requirements

Double door - with two vertical rod type exit devices.


3 1/2" Min. Stile