Trim Selection

Rim | Surface Vertical Rod | Surface Vertical Rod LBR | Selector Chart | Trim Selection | Strikes and Accessories | Alarm Exit Hardware | Fire Exit Hardware | Electrification & Power Supplies | ADA Compliant Hardware | Templates | General Information | Print Catalog Page

Trim Selection
ANSI A156.3, Grade 1

Lever Design

GN Design AT Design Spa Design
TUB Design 8000K  
 

When ordering "AT" and "SPA" designs, prefix design name before part number. Example: ENTOOL in "AT" design is ATENT00L.

Keyway

6 pin solid brass "C" keyway standard. Optional: Schlage E, Schlage C-K, Russwin D1-2-3-4, Corbin 59/60, Sargent LA-LB-LC, Falcon/Weiser E, Arrow A, Yale 8, Yale GA and Kwikset. Can also accept Medeco, Assa and Kaba High Security Cylinders.

Escutcheon Lever Design

Construction

  • Grade 1, thrubolted design, rigid non-clutch. Non-handed design.
  • Easily field reversible.
  • Hardened steel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

Finishes

  • Powder coated Aluminum (Alum)
  • Powder coated Dark Bronze Duranodic (DURO)
  • Powder coated Gold

Door Thickness

Standard 1-3/4". For 2-1/4" thick door use additional PART # TAIL3.

Escutcheon Dimensions

2-3/4" width x 8-3/4" length. Lever length: 4-3/4". Fits and covers
2-1/8" 161 cutout.

  • NESC2200 or ICNESC2200 or ICSCNESC2200 - ENTRANCE
    • Rigid Entrance, key locks or unlocks escutcheon trim.
    • Operates as classroom function.
    • ANSI Function - 63
  • NESC2205 or ICNESC2205 or ICSCNESC2205 - STOREROOM
    • Rigid Storeroom, key unlocks lever, lever retracts latch bolt, otherwise always locked.
    • ANSI Function - 04
  • NESC2230 - PASSAGE
    • Trim always operable and free
    • ANSI Function - 62
  • NESC2240 - DUMMY
    • Dummy Escutcheon trim.
    • ANSI Function - 10

Keyway

6 pin solid brass "C" keyway standard. Optional: Schlage E, Schlage C-K, Russwin D1-2-3-4, Corbin 59/60, Sargent LA-LB-LC, Falcon/Weiser E, Arrow A, Yale 8, Yale GA and Kwikset. Can also accept Medeco, Assa and Kaba High Security Cylinders.

  • (IC) INTERCHANGEABLE CORE
    • Interchangeable Core locks will accept compatible 6 or 7 pin cores with BEST, FALCON and ARROW
  • (ICSC) INTERCHANGEABLE CORE
    • Indicates function available with Schlage Full size format Interchangeable Core.

Pull Design

2200PULNL or IC2200PULNL or ICSC2200PULNL 2200NL or IC2200NL or ICSC2200NL 2200 DTP 2200 EOP 8000K Entrance
  • For Rim Devices Only
  • Outside by pull and key.
  • Key retracts latch bolt.
  • ANSI function - 03.
  • Covers 161 cutout.
  • Standard Rim Cylinder available in "C" 6 pin & optional Kwikset KW keyways.
  • For Rim Devices Only
  • Outside by pull and key.
  • Key retracts latch bolt.
  • ANSI function - 03
  • Covers 161 cutout.
  • Standard Rim Cylinder available in "C" 6 pin & optional Kwikset KW keyways.
  • Outside by pull only.
  • Pull when dogged.
  • ANSI Function - 02
  • Covers 161 cutout
  • Outside by plate only.
  • ANSI function - 10
  • Covers 161 cutout.
  • Key locks and unlocks knob.
  • Operates as classroom function.
  • ANSI Function - 08

Thumbpiece Trim

(Operates on Rim & Vertical Rod Devices)

  • THP00 or ICTHP00 or ICSCTHP00- ENTRANCE
    • Key locks or unlocks thumbpiece.
    • Operates as classroom function.
    • ANSI Function - 63
  • THP05 or ICTHP05 or ICSCTHP05 - STOREROOM
    • Key unlocks thumbpiece, thumbpiece retracts latch bolt, otherwise always locked.
    • ANSI Function - 04
  • THP30 - PASSAGE
    • Trim always operable and free
    • ANSI Function - 63
  • THP40 - DUMMY
    • Dummy trim. Includes blank Mortise dummy cylinder.
    • ANSI Function - 10

Finishes

Powder coated Aluminum (Alum), Dark Bronze Duranodic (DURO), Gold for Pull and Thumbpiece trims. US32D, US3, US10B for 8000K knob trim.

Keyway

6 pin solid brass "C" keyway standard. Optional: Schlage E, Schlage C-K, Russwin D1-2-3-4, Corbin 59/60, Sargent LA-LB-LC, Falcon/Weiser E, Arrow A, Yale 8, Yale GA and Kwikset. Can also accept Medeco, Assa and Kaba High Security Cylinders.

  • (IC) INTERCHANGEABLE CORE
    • Interchangeable Core locks will accept compatible 6 or 7 pin cores with BEST, FALCON and ARROW
  • (ICSC) INTERCHANGEABLE CORE
    • Indicates function available with Schlage Full size format Interchangeable Core.

Door Thickness

Standard 1 3/4". For 2 1/4" thick door, use additional PART # TAIL7.

Electrified Lever Trim

Cal-Royal's electrified lever trim provides remote locking and
unlocking capabilities while incorporating the patented clutch trim
design. The 24V DC solenoid can be energized from a distant
controller, thus allowing access control of the opening.

The control of stairwells in high-rise buildings is a common
application for this trim, where electric pullback of the exit
device's latchbolt is cost prohibitive or not required. This is
especially practical in applications where fire/life safety codes
require a "fail-safe" condition which is not an option with
electrified latch pullback devices. Because the current draw is
quite low there is no need for a more expensive power supply to
provide the surge current.

Features

Options

Specifications

Solenoid....................................... Continuous Duty 24VDC
Operating Voltage........................ 12 or 24VAC/DC + OR - 10% (must specify 12 or 24 volts when ordering)
Amperage..................................... 260mA@12V / 160mA@24V
Coil Resistance............................ 12V=49Ω / 24V=159Ω
 

To order, Specify:
OPTIONS: FAIL SAFE (FS)
                FAIL SECURE (FSE)

 

ITEM # DESCRIPTION
FS12 ESC22 FS12 FAIL-SAFE OPTION 12V AC/DC
FS24 ESC22 FS24 FAIL-SAFE OPTION 24V AC/DC
FSE12 ESC22 FSE12 FAIL-SECURE OPTION 12V AC/DC
FSE24 ESC22 FSE24 FAIL-SECURE OPTION 24V AC/DC

(ELR)Electrified Latch Retraction

Our electrified latch pullback exit device allows for remote keyless access control in high occupancy/high traffic conditions where exit devices are required. Common applications include conditions such as hospitals, airports, schools, churches and they are commonly specified in applications that require automatic door openers. The device may be continuously energized allowing for a push/pull condition if desired.

Features

Specifications

Voltage.......................................24VDC
Amperage..................................... Surge current - 6.5A for 150ms@24V / Holding - 250mA@24V
Coil Resistance............................ 3.7Ω
 

To order, Specify:

Signal Switch RX and LX

RX (request to exit) signal switch is used to signal the use of an opening from the push side. When the push pad is depressed, the switch is activated. These devices are equipped with an internal SPDT (single pole double throw) switch that monitors the touch bar.

LX (latch bolt monitoring) signal switch monitors both egress and access of an opening. When the latch bolt is retracted, the switch is activated. These devices are equipped with an internal SPDT (single pole double throw) switch that monitors the latch bolt position.

LX and RX switches can be combined.

LX, RX switches can be used in combination with EL (electric latch retraction) option.

Specifications

RX or LX...................Switch rated 0.5 amps @ 24VAC/DC resistive
Low current RX or LX.................. Switch rated 0.5 amps @ 24VAC/DC resistive
 

For Factory Installed:

To order, Specify: